| ■ BTB-9S Mini- Type Machine (Low Power
Inverter )
|
|
Product
Character
This series is economy low power inverter
,It fits speed regulation of three-phase asynchrony
and some common non-precision drive occasion.
Simple operation, practicality and safety,
to satisfy your many demand on the low cost.
It kept customer parameter region, It can make special or
unconventional function for you.
|
 |
|
| |
Keyboard layout
and function
explanation of BTB-9S mini-type
|
 |
 |
key-press of keyboard function list |
|
key-press
|
key-press name
|
function
|
| PRG |
Program Key
|
The first press,
enter function code ,press again enter parameter of function, once again return function
code
|
| SET |
Set
Key
|
factor
set , press this key to store factor of modification when
running or stopping , to choose different display
content |
 |
Increase
Key
|
when
setting :to add function code or add content of
parameter when running :if
use number give, then adding reference input give, that is digital keyboard
potentiometer function |
 |
Decrease Key
|
when
setting :decrease function code or decrease content of
factor
when running : if use number
give, then adding reference
input give, that
is digital keyboard potentiometer function
|
| RUN |
Run
Key
|
when
setting keyboard control , send run command
,start inverter to work
|
STOP /
RESET |
Stop
Key
|
when
keyboard controlling , press this key to stop malfunction
state : reset malfunction . program set : exit
to set |
|
|
The arrangement of control loop
terminal
|
 |
|
Function of control loop terminal
|
| |
Category
|
Terminal
Signal
|
Name
|
Function
Explanation
|
Signal
Level
|
|
control signal
|
COM |
public terminal of +24V
|
-- |
-- |
| RUN |
RUN
|
effective when close with COM
|
photo coupling
isolation |
| F / R |
forward/reverse
run control
terminal
|
effective
when close with COM
|
| X1~X3 |
multi speed input
terminal
|
effective when close with COM
|
| FRE |
multifunction input
|
effective
when close with COM
|
|
switch output
|
TA2,TB2,TC2 |
multifunction output
|
programmable output
|
250V/1A |
| TA3,TB3,TC3 |
|
analog input and output signal
|
V10 |
signal power 10V
|
analog +10V power
|
10V/5mA |
| VG |
analog give
input
|
0~10V |
0~10V |
| VF |
voltage feedback signal
|
0~10V |
0~10V |
| IF |
current feedback signal
|
4~20mA |
4~20mA |
| FM |
frequency meter output
|
0~10V |
(reserve )
|
| IM |
current meter output
|
0~10V |
(reserve )
|
| GND |
public
terminal
|
-- |
-- |
assistant power
|
+24V
COM |
24V assistant power
|
+24V |
24V
200mA |
|
|
Standard Hookup
|
 |
|
Installation and Exterior
Dimension Diagram
|
|
BTB-9S 安装尺寸(mm )Installation
Dimension (mm)
|
| W × H × D = 112 × 170 × 160 |
| |
| |
|