DATA-LINC:Metallurgy.Traffic.Port.Electric power.Water conservancy.Oil.Mining.Natural gasDATA-LINC:Metallurgy.Traffic.Port.Electric power.Water conservancy.Oil.Mining.Natural gasDATA-LINC:Metallurgy.Traffic.Port.Electric power.Water conservancy.Oil.Mining.Natural gasDATA-LINC:Metallurgy.Traffic.Port.Electric power.Water conservancy.Oil.Mining.Natural gasDATA-LINC:Metallurgy.Traffic.Port.Electric power.Water conservancy.Oil.Mining.Natural gas
DATA-LINC DATA-LINC DATA-LINC  
License-free and wireless-operates in the2.4 to 2.483 GHz Industrial, Scientific and Medical (ISM) spread spectrum band

Maximum immunity to interference, even in high noise environments

Factory or field configured for your application-ensuring trouble-free installation

User configurable for master, remote,
repeater or repeater/remote mode

Frequency key options allow for different
systems to operate simultaneously in close  
proximity

Rated range of up to 20 miles (32 km) and
an installed range of up to 30 miles (48 km) with line-of-sight/omni directional antenna-
further with repeaters

Wireless Diagnose/Manage Software:LincView OPC
LincView OPC of Data-Linc Group    

Data-Linc Group's  LincView TM OPC (OLE for Process Control), Data-Linc's enhanced diagnostics/management software, allows the monitoring and control of networks utilizing wireless SRM Family modems. LincView OPC is particularly suited to troubleshooting and analyzing the performance of RF links in large SCADA networks, saving time and increasing confidence in the network's reliability.

LincView OPC Features

  • Simplifies monitoring and control of large, complex networks
  • Offers OPC server capability
  • Graphically displays view of entire wireless network
  • Provides programmable warning/alarms with logging
  • Displays both ends of all RF links
  • Supports multiple radio networks
  • Timestamps last communication
  • Delivers historical graphing of key statistics and values
  • Allows re-configuration of each network modem (RF link must first be present)

LincView OPC Software is compatible with Data-Linc SRM serial and Ethernet radio modems, runs on a PC with Windows® operating system and provides essential information for each modem in the network.

Taking advantage of internal improvements in the SRM family of wireless Ethernet and serial modems, Data-Linc's latest diagnostic option, LincView OPC is a new user interface with an internal OPC server.

Wireless Diagnose/Manage Software:LincView OPC
Immediate/dynamic diagnosing: Connect window

PThe LincView OPC user interface displays
real time dynamic diagnostic information both
graphically and textually, as well as simultaneously with normal network use. This same diagnostic information can be viewed as tags in your familiar OPC browser and utilized in OPC enabled applications. LincView and/or your HMI can provide diagnostic alarm, log, trend and archive services.

 

 

Wireless Diagnose/Manage Software:LincView OPC
Immediate/dynamic diagnosing: Network topology window

Information is provided for each radio including a tree view of network topology. Examples of typical parameters include environmental (temperature, voltage), RF (signal and noise levels at each end of the RF path, percent receive rate, frequency drift), data performance (bytes sent or received, receive rate), and informational (time since last response). Units can be English, Metric, dBm, J-units, Celsius or Degrees as appropriate. Additionally, from LincView OPC's user interface, each radio can be named and its configuration parameters viewed or modified.  

Wireless Diagnose/Manage Software:LincView OPC
Immediate/dynamic diagnosing: Main setup window          

LincView OPC communicates with the network's Master radio using RS232, UDP, or TCP/IP (via a terminal server), as selected by the user. LincView OPC, the OPC client, and the radio network can be located at or on the same PC or at great distances from each other. Additionally, LincView OPC supports multiple radio networks via multiple sessions.    

 

 

Wireless Diagnose/Manage Software:LincView OPC
Immediate/dynamic diagnosing: RSView Tag message window

LincView OPC, provided on CD, installs on Windows 98, NT, 2000, and XP based computers. Newer Data-Linc SRM 900MHz band radio modems with call numbers of 911-xxxx and greater or SRM 2.4 GHz modems with call numbers of 241-xxxx and greater are required (Other radios are supported by prior non-OPC LincView versions). For certain limited situations Master radios can be factory ordered with an optional RS232 diagnostic
port or purchased separately for field installation.

 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC Servo
Semiconductor / IGBT / Diode , Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter /, PLC Cables UPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.