Jonweb FA, Japan FA, 日本工控网

Always Changes For The Better! 

Fuji Factory Automation Products: Fuji PLC, Fuji LVS, Fuji PLC, Fuji Inverter, Fuji Servo, Fuji HMI, Fuji POD Fuji Inverter, Fuji PLC, Fuji Servo, Fuji HMI, LVS, Come From:JonWeb Technology! 
  中文访问 HOME CONTACT Selling  Price Fuji Inverter Fuji PLC Fuji HMI Fuji Power Distribution Fuji Servo User Manual
 
Jonweb FA:
Siemens PLC & Siemens HMI, Siemens Inverter
Allen Bradley PLC
Mitsubishi PLC & Mitsubishi Inverter
Semiconductor
Yaskawa Inverter
Fuji AC Servo System
Cisco Router & Switche
 
On Requested:
Schneider PLC
Mean Well
APC UPS Power Supply
Proface HMI
LG PLC / Inverter
VIPA PLC / HMI
Sanyo Denki
BTB Inverter
Fluke Meters
Tektronix Oscilloscopes
Agilent
Hioki Tester
Panasonic
Omron
Toshiba
Hitachi
Idec
Sanken
Koyo
Meiden
Nikki Denso
Keyence
Oriental
 
Also Supply:
 -> 枕头 / 床垫
 -> Fuel Additive - STR2020
Contact Method
China/Beijing
    TeL:+86-10-86360099
            +86-10-62988280
    Fax:+86-10-62985883
MSN:
  cn5130@hotmail.com 
Email :
  ZhengJon@yahoo.com 
Any Call:
  +86-13001958500
Skype ID:  japanfa.com

More Detail...

 
GuestBook
  Send messages to us online.
Send messages to us online.
 
  
Sell your FA to China?
 
> Fuji Products Center   >  Fuji HMI > UG230 Series 
Product Information
Specification [UG230 Series]
General specifications
Tipe/Item UG230
Power supply Rated voltage 24VDC
Permissible range of voltage 24VDC±10%
Permissible momentary
power failure
Within 1ms
Power consumption
(Maximum rating)
16W or less
Inrush current 20A or less (with a rise time 0.1ms)
Withstand voltage DC external terminals to FG: 500VAC, 1 minute
Insulation resistance 500VDC, 10MΩ or above
Physical environment Ambient temperature 0ºC to +50ºC *
Storage ambient temperature -10ºC to +60ºC
Ambient humidity 85% RH or less (Avoid condensation)
Solvent resistance No cutting oil or organic solvent clung to the unit
Atmosphere No corrosive gas or conductive dust
Operating altitude Altitude 2000m or less
Mechanical operating conditions Vibration resistance Vibration frequency: 10 to 150Hz, Acceleration: 9.8m/s2
One-way deflection: 0.075mm, X, Y, Z: 3 directions for one hour
Shock resistance Pulse shape: half sine wave
Peak acceleration: 147m/s2, X, Y, Z: 3 directions, six times each
Electrical  operating conditions Noise immunity 1000Vp-p (pulse width 1µs, rise time: 1ns)
Anti-static electricity
discharge
Conforming to IEC61000-4-2, contact: 6kV, air: 8kV
Mounting conditions Grounding Grounding resistance: less than 100Ω
Structure Degree of protection: front panel: IP65 (using waterproof gasket)
rear case: IP20
Form: in a single body
Mounting method: panel flush mounting

Although the UG series has high environmental resistance characteristics equivalent to IP65F, it is expressed as IP65 herein in order to avoid confusion, as measures are required to meet the long-hour oil resistance, which is higher than the IP standard.
Cooling system Natural cooling
Mass Unit only: approx. 680g, with UG230A-DCL installed: approx. 820g
Case color Black (Munsell N2.0)
Case material PC/PS resin
* As for UG230H-SS and UG230H-LS, the display quality might deteriorate and the contrast be weaken when operated for a long period of time at ambient temperature 40 to 50ºC.
Display specifications
Tipe/Item UG230H-LS UG230H-SS UG230H-TS
Display device Monochrome LCD STN color LCD TFT color LCD
Display size 5.7-inch
Colors Monochrome, 8 gradations + blinks 32,768 colors +16-color blinks
Resolution W x H (dots) 320 x 240
Dot pitch W x H (mm) 0.36 x 0.36
Brightness (cd/m2) 220 160 350
Contrast ratio 5?F1 30?F1 60?F1
Angle of vertical visibility +20º, -40º +20º, -35º +65º, -40º
Angle of horizontal visibility ±45º ±50º ±65º
Backlight
Cold cathode fluorescent lamp
Average backlight life *1 Approx. 58,000h Approx. 54,000h Approx. 50,000h
Backlight auto OFF function Always ON, arbitrary setting
Contrast adjustment Provided *2 Not provided
Brightness adjustment Not provided 128 levels *2
Surface sheet Material: Polycarbonate, 0.3mm thick
POWER lamp ON (green) when the power is supplied.
ON (orange) when the voltage of the battery connected has become low.
*1 At the time when the surface brightness is down to 50% of the initial value at normal temperature of 25ºC.
*2 Adjustment by a function switch or macrocommand.
 

Supplier:   JonWeb Technology Trade CO.,LTD 
Room 902, Shangdi Garden 23, Shangdi East Road, Haidian District, Beijing, China (Zip: 100085)
Easy Call: +86-13001958500 (24hours Hotline) ,    Tel: +86-10-62988280 / 86360099,      Fax: +86-10-62985883
MSN:    cn5130@hotmail.com   /   Email: ZhengJon@Yahoo.com    /  Skype Chat  ID:  
japanfa.com


Stronger on: Siemens PLC / Siemens Inverter / Siemens HMI , Mitsubishi PLC / Mitsubishi Inverter / Mitsubishi AC Servo , Fuji AC ServoSemiconductor / IGBT / Diode , Allen Bradley / Allen Bradley PLC,   VIPA PLC / VIPA HMI Yaskawa Inverter , PLC Cables Cisco / Cisco Router / Cisco SwitchUPS / APC UPS , Latex Pillows / Latex Mattress  , STR2020  Etec.