Fuji Low-Noise,
Compact-Type Inverters
FVR-E11S Series
 |

(Available only in
Japan)
- Rated AC input voltage
| 3-phase
200V |
: |
200
to 230V 50/60Hz |
| Single-phase
200V |
: |
200
to 240V 50/60Hz |
| 3-phase
400V |
: |
380
to 480V 50/60Hz |
- Allowable variation
| Voltage |
: |
+10%
to -15% (3-phase) |
|
+10%
to -10%
(single-phase) |
| Frequency |
: |
+5%
to -5% |
| _ |
Imbalance
rate
in power supply
voltage |
: |
2%
or less (for
3-phase only)
(Conforms to
IEC61800-3(5.2.3)) |
- Product range
| 3-phase
200V |
: |
0.1
to 7.5kW |
| Single-phase
200V |
: |
0.1
to 2.2kW |
| 3-phase
400V |
: |
0.4
to 7.5kW |
|


|
|
 |
|
|
|

 |

Fuji Low-Noise,
Compact-Type Inverters
FVR-E11S Series
 |

(Available only in
Japan)

| Series |
FVR-E11S |
| Output overload
capability |
200% of
rated current for 0.5s, 150%
of rated current for 1min. |
| Braking
torque |
Regenerative braking |
| 3-phase 200V |
: |
100% or more (0.1,
0.2kW) |
|
|
70% or more (0.4 to
1.5kW) |
|
|
40% or more (2.2,
3.7kW) |
|
|
20% or more (5.5,
7.5kW) |
| 3-phase 400V |
: |
100% or more (0.4,
0.75kW) |
|
|
50% or more (1.5 to
3.7kW) |
| Single-phase |
: |
100% or more (0.1,
0.2kW) |
|
|
70% or more (0.4,
0.75kW) |
|
|
40% or more (1.5,
2.2kW) |
|
| DC injection braking |
| Starting frequency |
: |
0.2 to 60Hz
(adjustable) |
| Braking time |
: |
0.01 to 30s
(adjustable) |
| Braking voltage |
: |
0 to 100%
(adjustable) |
|
| Acceleration/deceleration
time |
0.01 to
3600s
(Acceleration/deceleration can
be set independently.) |
| Multistep
frequency control |
16 steps |
| Frequency
setting signal |
0 to 5V DC,
0 to 10V DC, 4 to 20mA DC |
| Protective
functions |
Stall
prevention, overcurrent,
instantaneous power failure or
undervoltage, overvoltage,
inverter overheating, external
alarm (tripping of external
thermal overload relay), motor
overload (tripping of
electronic thermal overload),
CPU error, communications
error, output wiring fault,
output terminal short-circuit,
and ground fault of output
terminal at start up |
| Alarm relay
output |
SPDT
contact |
| Enclosure and
cooling method |
Totally
enclosed natural cooling type
(IP40)(0.75kW or less)
Totally enclosed fan cooling
type (IP40, except fan)(1.5 to
7.5kW) |
|
|
 |
 |
|
|
|
|
|
|