¡NCS-F
series
Specification of NCS-FS¦¦M series (for synchronouse motor) controllers
and servomotors |
|
| Item |
NCS-FS**M |
| -122 |
-242 |
-402 |
-752 |
-113 |
-153 |
-223 |
| Input power
|
Separated
power control source type
Main power AC200/220V, 50/60Hz, 3phase |
| Voltage range |
AC180V`AC242V@*2 |
| Main circuit
method |
IPM
4 quadrant bridge sine wave PWM control |
| Continuous
output current(rms) |
8.3A |
15.2A |
26A |
46A |
45A |
62A |
94A |
| Instantaneous
output current(rms) |
24.9A |
45.6A |
52A |
96A |
88A |
121A |
183A |
| Instantaneous
output torque |
200%@isome
motor combination 300%j |
| Control method
|
Semi-closed
loop by encoder feedback |
| Brake method
|
Regenerative
braking (option: Power regeneration) |
| Career
frequency |
10KHz |
| i7.5KHz,
10KHz, 15KHz, selectablej |
|
Speed control |
Speed regulation
|
}0.01%@iAverage
value: Temp./0`40Ž, Load/ Voltage fluctuationj |
| Speed
control range |
1
: 5000@*1 |
| Field
control range |
------------------------------------------ |
| Torque
limit |
External
analog torque limit command (DC voltage): 0`+10V (+3.3V/ Rate torque), Input
resistance about 20kĦ(resolution:10bits), Forward/ Reverse: 1 channel, each(total
2ch)
Internal digital torque limit value: Forward/ Reverse: 1 channel, each (parameter) |
| Position
control |
Pulse train
control |
Max.
frequency 1Mpps (at 4 times) |
| Pulse
train command method |
Line
driver method (directional pulse): Max.250Kpps
Line driver method (90‹ phase different 2 phase pulse): Max.250Kpps
Open collector method (directional pulse): Max.200Kpps |
| Pulse
train compensation |
1/100
… A/B … 100@iA,B : 1`65535j |
| Position
detection Pulse output |
90‹phase
different 2 phase pulse signal, Marker signal
Output style: Line driver output
Division ratio: 1/N (N=1`32) |
| Serial
communication |
RS-422A,
Start/ Stop synchro., Multi-drop wiring is possible, (Communication condition
parameter set is possible.) 56kbps |
| Monitor
function |
LCD module (installed),: Status display, Diagnostic display,
I/O signal display, Alarm display (last 5 cause history)
Analog monitor: Speed , Torque, Deviation, etc. (Selection by parameter)
|
| Control
function |
2 free
degree control, FF control, Vibration filter, R2 compensation, Auto. tuning,
Non-interacting compensation, Dead time compensation |
| Protective
function |
IPM
fault, Over voltage, Under voltage, Over speed, Over load, Encoder fault,
Deviation over flow, Communication error, Each data and parameter error
, etc.(Last 5 cause history is stored.) |
| Option |
Data
Input Unit (MDI unit), Servo ready display, Cables, etc. |
| Applicable
encoder |
6000
( 2000 ) ppr@iSelection by parameterj |
| Load
inertia |
10
times or less of motor rotor inertia |
| Power
capacity@*3 |
2.6kVA |
5.0kVA |
8.3kVA |
15.7kVA |
21kVA |
30kVA |
41kVA |
| No-fuse
breaker (rated current)*4 |
15A |
20A |
30A |
60A |
100A |
125A |
200A |
| Weight@*5 |
7.0kg |
7.0kg |
8.0kg |
12.5kg |
14.0kg |
26.5kg |
35.5kg |
Accessories
(Regenerative resistor) |
200W,40Ħ~1 |
400W,20Ħ~1 |
200W,40Ħ~3 |
500W,24Ħ~3 |
500W,24Ħ~4 |
500W,24Ħ~6 |
Applicable
motor type
(synchronous motor)
Motor specification and dimension can be referred to the motor catalogs
of NA700 series. |
NA720-122 |
NA720-182
-242 |
NA720-402 |
NA720-402
-552
-752 |
NA720-113 |
NA720-153 |
NA720-223 |
¦1. Speed control is defined that in the range a motor
does not stop with 100% load..
¦2. When power source voltage drops, rated output and rated speed is not
guaranteed.
¦3. It changes according to power source impedance.
¦4. Please choose sufficient shut down capacity type to conduct protective
coordinate with power source capacity.
¦5. Add 1.2kg to the described value of the type equipped with SQB (NCS-F22,
F23, F33, F34, F43, F44, F53, F54, F63, F64). |
@ |